Skip to main content

Mechanical installation and polar alignment

WD-15EFirmware: WD-15E mount build; AHC 1.1.0 interface reference

In this chapter

3.1 Installation preparation​

Place the 3.0 kg WD-15E head on a stable padded surface, inspect the body and sockets, and identify the actual model label. The relatively light head can still tip when its latitude angle or axis position changes. Keep a hand on it until it is secured to the support.

Use the rigid body and base while handling the head. Do not lift or squeeze it by an axis joint, saddle socket, adjustment screw or connector.
WD-15E mount head and latitude support in an angled product view
CAUTION · Protect the joints and seals

Grip the rigid body and base. Do not lift the mount by the black rotating connection between body and base or compress its dust-cover area; deformation may affect fit or dust protection. Do not pull on an adjuster handle or use a USB-C plug as a carrying handle.

Do not grip, squeeze or lift by the highlighted dust-cover sleeve. Support the rigid body and base instead.
Full cylindrical dust-cover wall highlighted pale red

Before mounting a telescope, check that the saddle clamps move freely, that each adjuster has reasonable travel and that no connector is loose. Stop if you find damage or an unidentified fastener; do not force it.

3.2 Install the tripod​

For a portable WD-15E setup, choose a tripod rigid enough to carry the mount, optical payload, any counterweights, accessories and dynamic slew loads. Extend the legs as little as practical, secure the leg locks and spreader, and keep the footprint wide. A fixed pier or folding pier may also be used with a compatible, securely attached adapter. Recheck the support after moving the setup or changing a heavy camera.

WARNING · Tipping risk

An optical tube can place the combined center of gravity outside the tripod footprint even when the mount head is small. Check the complete setup in both intended pier-side orientations, including camera, shaft and counterweights. Do not leave a loaded mount on a table, an unsecured adapter or an unanchored narrow support.

A lightweight carbon-fiber tripod can be portable but may flex under guiding corrections or wind; evaluate its rigidity with the actual telescope and ground conditions. Counterweights can reduce an unbalanced RA moment, but they add total mass and can create another tipping or collision path.

Tripod example: secure the leg locks and spreader; keep extensions low.
WD-15E on a portable tripod with short leg extensions

The illustrated tripod and adapter geometry is not a WD-15E mounting-hole or load-rating specification.

3.3 Install the mount​

The official WD-15E drawing identifies a 3/8-inch attachment and M6 bolt positions on the base. Use an adapter designed for this WD-15E pattern. For a heavier configuration, use all mounting points required by the chosen adapter rather than relying on one loose center connection.

  1. Confirm the adapter is secured to the support and provides full, flat contact under the mount.
  2. Hold the mount continuously as you align the base with the adapter.
  3. Select the fastener type and length for this base and adapter. Thread each fastener by hand first. It must engage sufficiently to secure the mount without bottoming in the base, interfering with internal parts or forcing the mount apart. The WD-20E/WD-20EP insertion-depth value must not be assumed for WD-15E.
  4. Tighten the required fasteners with an appropriate hand tool following the adapter's instructions. Check for rocking, loose joints and interference with azimuth adjustment.
CAUTION · Screw length

A screw can appear tight because it bottoms out while leaving the mount unsecured, or it can damage the base when forced too far. If permitted engagement depth is not specified for your adapter and WD-15E hardware, obtain the correct fastener specification from WarpAstron support before installation. Never substitute a mismatched M6 or 3/8-inch thread.

3.4 Install the telescope and accessories​

The saddle accepts Vixen and Losmandy dovetail profiles. Check that the telescope's actual bar matches one profile and is long and rigid enough for the load. Use only WD-15E-compatible replacement clamp hardware if a knob is damaged. Keep the clamps and dovetail free of dirt that could prevent full seating.

  1. With the mount secured and movement stopped, support the telescope's full weight.
  2. Open the saddle clamps sufficiently for the correct dovetail channel; do not remove hardware unnecessarily.
  3. Place the dovetail fully into the profile and tighten the applicable clamps evenly. Check that both contact points actually engage the bar rather than the edge of a wrong-sized plate.
  4. While still supporting the OTA, gently check retention. Secure camera, focuser, finder and cable attachments.
  5. Adjust the telescope's fore–aft position only while it remains supported, then retighten and check clamp retention again.
Use the profile that matches the actual dovetail bar.
Wide Losmandy and narrow Vixen channels on the WD-15E saddle
Losmandy is the wider profile; Vixen is the narrower profile. Labels identify the contact surfaces, not a manufacturing dimension.
End profile identifying the two WD-15E clamp contact heights
WARNING · A dovetail can slip suddenly

Never loosen either clamp with the optical tube unsupported. A side-facing or inverted saddle can drop an incorrectly seated tube without warning.

3.5 Payload and counterweight setup​

The WD-15E product specifications list 8 kg standard without counterweights and 13 kg maximum allowed with counterweights at a 20 cm RA lever arm. The supplied WD-15E capacity chart also gives a separate 8 N·m recommendation and 10.5 N·m maximum for operation without counterweights. Apply both checks independently and use the more restrictive result. A maximum-allowed figure means the mount can move the load; it does not guarantee imaging performance or whole-system stability. Include the optical tube, rings, dovetail, camera, filters, guidescope, focuser, adapters and any saddle-mounted device in the optical payload.

For a static estimate of gravitational moment about the RA axis:

Moment (N·m) = mass (kg) × 9.81 × perpendicular RA lever arm (m)
= mass (kg) × 0.0981 × perpendicular RA lever arm (cm)

The chart calls the optical center of gravity's distance from the dovetail plate L1 and its distance from the RA axis L2. For the illustrated standard geometry, L2 ≈ L1 + 8.3 cm. Enter the measured L2 in the calculator; the 8.3 cm offset is an illustration, not a substitute for measuring a changed saddle or adapter. Evaluate the worst relevant orientation because moving a camera or extending a focuser changes the center of gravity.

L1: center of gravity above dovetailL2: center of gravity from RA axisRecommended without counterweightsMaximum without counterweights
5 cm13.3 cm6.1 kg8.1 kg
11.7 cm20 cm4.1 kg5.4 kg
20 cm28.3 cm2.9 kg3.8 kg

The curve is based on 8 N·m ÷ (gravity × L2 in meters) and 10.5 N·m ÷ (gravity × L2 in meters). The chart labels are rounded; the calculator uses 9.81 m/s², so a displayed mass may differ by 0.1 kg near a rounding boundary. The product-page mass figures and the supplied torque chart do not yield the same allowable mass at 20 cm. For example, 8 kg at 20 cm produces about 15.7 N·m, above the chart's 10.5 N·m counterweight-free maximum. Do not treat the mass figure alone as clearance for that arrangement; use the more restrictive chart result and contact WarpAstron support if a configuration approaches either limit.

WD-15E load-capacity reference. Open the image to inspect the geometry and curves at full size.
WD-15E capacity chart with L1 and L2 geometry, examples, and recommended 8 N·m and maximum 10.5 N·m no-counterweight curves

Counterweights​

The counterweight-shaft attachment is M12 × 1.75. Use a compatible shaft, support each weight while fitting it, secure its clamp and fit a positive end stop. A counterweight on the opposing side can reduce residual static RA moment: subtract its moment from that of the optical load, then consider the magnitude and direction of the result. If using several weights, sum their masses and use a mass-weighted average of their lever arms for a single calculator entry.

The supplied 8/10.5 N·m thresholds are explicitly for operation without a counterweight. No WD-15E combined counterweight-mass maximum or counterweighted RA-moment threshold is supplied here. Do not transfer the WD-20E/WD-20EP 10 kg shaft limit, 50/60 N·m torque values or 45 N·m brake rating to this model. Ask WarpAstron support for a WD-15E-specific shaft or counterweighted-load assessment when your arrangement needs those numerical limits. A smaller residual moment does not cancel the added mass, inertia, support loading or collision path of counterweights.

WARNING · No mechanical brake

WD-15E motor holding torque exists only while the drive has suitable power. Even a setup within the no-counterweight moment recommendation can move when USB-C input power is lost. Arrange the OTA and any weights conservatively, keep the telescope supported during changes, and assess what happens on sudden power loss before leaving the mount unattended.

Do not use a payload calculation to override the dovetail, tripod, adapter, shaft or clearance rating. A stable, stiff support and secure connectors matter as much as the nominal payload mass.

Estimate your setup​

Enter the complete optical payload and its perpendicular distance L2 from the RA axis. Without counterweights, the tool derives recommended and maximum masses at your entered L2 from the 8/10.5 N·m chart and checks the actual moment. If counterweights are fitted, enter their combined mass and effective opposing lever arm: the tool then shows residual moment, but does not apply the counterweight-free thresholds to that configuration. It also compares the separate published 8/13 kg optical-mass figures at their 20 cm RA reference. An estimate cannot certify a safe setup or infer an unpublished counterweighted torque or counterweight-mass limit.

WD-15E static RA torque estimator

Example values are editable. Use actual measurements in the worst relevant orientation. All distances are perpendicular lever arms from the RA axis, in centimeters.

Optical payload
Payload torque
7.8 N·m
Opposing counterweight torque
0.0 N·m
Residual RA torque (magnitude)
7.8 N·m
Load direction
Payload side
Recommended mass at this RA arm (8 N·m)
4.1 kg
Maximum mass at this RA arm (10.5 N·m)
5.4 kg
  • Optical mass: At or below the published 8 kg standard recommendation without counterweights, specified at a 20 cm RA lever arm.
  • WD-15E RA moment: Within the 8 N·m no-counterweight recommendation for this static estimate.
  • Reference geometry: The entered RA lever arm is at or below the published 20 cm reference; check all other limits independently.

Added counterweight mass: 0.0 kg. Include the mount, shaft, adapters and all equipment when checking the support's load rating.

The 8 N·m recommendation and 10.5 N·m maximum are for operation without counterweights in the supplied WD-15E load chart; they are independent of the published optical-mass figures. Apply the more restrictive result. No WD-15E counterweight-mass or counterweighted torque limit is supplied here. This static estimate does not certify safe operation or assess tipping, inertia, wind, stiffness, cable drag, bearing loads, power-loss motion or clearance.

3.6 Latitude and azimuth adjustment​

In GEM mode, the polar-axis elevation should initially approximate the absolute value of the observing latitude. The WD-15E provides 0–90° latitude in three coarse positions, each with a 30° fine-adjustment range, and ±8° azimuth adjustment. Use coarse positioning to enter the correct 30° range; do not force a fine adjuster to span the whole 90°.

Coarse latitude setting​

Three coarse positions provide 30° fine-adjustment ranges across the full 0–90° range. These are illustrative positions, not exact range boundaries.
WD-15E side views showing three coarse latitude positions
WARNING · Unload before moving the range

Remove the telescope and attached load before releasing a coarse-range fastener. Secure the base to its support and hold the mount body so the latitude assembly cannot drop.

  1. With the optical load removed and the body supported, slightly release both latitude locks counterclockwise when viewed from each handle's outer end.
  2. Use the fine adjuster to align the range screw hole completely with its access opening.
  3. Remove the range-setting screw with a correctly fitting manual hex key while supporting the body.
  4. Move the supported body to the selected coarse position, then align the holes completely again.
  5. Start the screw by hand and fully screw it in and secure it. Stop if the threads do not engage freely.
  6. Secure both latitude locks clockwise from each handle's outer end, then check stability before adding the telescope.
1. Unload the telescope, support the body and slightly release both latitude locks.
Coarse latitude step 1: release both latitude locks counterclockwise from each knob end
2. Use the fine adjuster to align the screw hole and access opening completely.
Coarse latitude step 2: align the screw hole completely with the access opening
3. Remove the range-setting screw with a correctly fitting manual hex key; keep the body supported.
Coarse latitude step 3: remove the aligned range-setting screw with a manual hex key
4. Select the coarse position while supporting the body, then align the holes again.
Coarse latitude step 4: move the supported body to the selected coarse position
5. Start by hand, fully insert and secure the screw. Stop if the threads do not engage freely.
Coarse latitude step 5: fully insert and tighten the range-setting screw
6. Secure both latitude locks clockwise when viewed from each knob end; check stability before installing the telescope.
Coarse latitude step 6: tighten both latitude locks clockwise from each knob end
CAUTION · Hole alignment and full engagement

Keep the body supported throughout the coarse-range change. The range screw must be fully engaged and secured before moving the mount, adding a load or commanding axis motion. Do not force misaligned threads or operate with the screw partly inserted.

Latitude fine adjustment​

Make small changes while watching a polar-alignment measurement. For routine small corrections, keep the locking handles in the position specified for the WD-15E mechanism so the polar axis does not shift when retightened. For a larger correction or unexpected resistance, release the locks as required, adjust gradually, secure them again and remeasure. The fine travel is limited to 30° within the selected coarse range. If an end stop is reached, unload the mount and change coarse range; never force the screw.

Viewed directly from the fine-adjustment handle end, clockwise rotation raises the polar-axis elevation; counterclockwise rotation lowers it. The arrows indicate direction, not an adjustment amount. Check the response with a small turn before a larger correction.

Clockwise raises latitude when viewed from the handle end. Use small turns and watch the alignment measurement.
Clockwise rotation viewed from the latitude handle end raises the polar-axis elevation
Counterclockwise lowers latitude when viewed from the handle end. Use small turns and watch the alignment measurement.
Counterclockwise rotation viewed from the latitude handle end lowers the polar-axis elevation

Azimuth fine adjustment​

Aim the whole tripod or pier close enough to the celestial pole that the ±8° azimuth adjusters can finish the correction. Release the azimuth locks only enough for movement, back off the opposed adjuster before advancing the other, and keep both in contact without forcing them against each other. Retighten and repeat the alignment measurement. Verify the response to a small turn on your actual WD-15E before making a large adjustment.

Release both azimuth locks slightly; do not remove the locking parts.
Slightly loosen both WD-15E azimuth locks before adjustment

The diagrams identify the opposed adjusters as A and B. Knob rotation is viewed from each knob's outer end; mount rotation is viewed from above.

Desired mount rotation, viewed from aboveBack off firstThen advance
CounterclockwiseB counterclockwiseA clockwise
ClockwiseA counterclockwiseB clockwise
Back off one side before advancing the other. Knob arrows use each outer-end view; the large arrows show mount rotation from above.
WD-15E azimuth direction comparison: back off B and advance A for counterclockwise rotation; reverse the pair for clockwise rotation
Bring both adjusters into suitable contact without forcing the opposed screws against each other.
Bring both opposed azimuth adjusters into suitable contact without forcing them against each other
Secure both azimuth locks and remeasure polar alignment.
Secure both azimuth locks after adjustment and recheck polar alignment

3.7 Polar alignment​

Polar alignment physically aims the RA axis at the celestial pole. It is different from GoTo alignment, coordinate Sync, Home and Park. Plate-solving routines in N.I.N.A., StellarMate/Ekos or ASIAIR are practical options when supported by the connected camera and mount. Watch any software-commanded rotation and keep the path clear.

  1. Confirm GEM mode, correct site and time, and an approximate polar-axis direction.
  2. Run the selected alignment routine. Stop for an implausible plate solve, unexpected slew or cable tension.
  3. Apply the requested corrections with the mechanical latitude and azimuth adjusters, not by changing sky coordinates.
  4. Secure any locks that were released, run a fresh measurement and aim for less than 2 arcminutes (2′) error when conditions permit. A second pass helps verify the first result.
  5. Recheck after installing or repositioning a heavy camera or telescope.

The RA absolute encoder corrects drive-position error; it cannot remove slow drift caused by significant polar-axis misalignment.

Optical-tube center of gravity and polar-axis stability​

A long OTA whose center of gravity moves fore and aft as the axes turn can shift the latitude mechanism. Reposition the OTA while supporting it, or use an appropriate counterweight arrangement, so the combined load does not rock the polar setting. Check alignment in representative positions rather than tightening a latitude lock harder to compensate.

Aim the physical RA axis at the celestial pole. Its elevation corresponds to observing latitude in GEM mode.
Mechanical RA axis aimed at the celestial pole with a horizon reference

3.8 Cable routing and movement clearance​

Keep the USB-C PD input cable strain-relieved at the mount and leave enough slack for the intended travel. Route saddle Port A's accessory power and Port B's computer data cable separately if both are used. Keep all cables outside the saddle clamp and away from the counterweight shaft, tripod legs, latitude mechanism and closing axis gaps.

CAUTION · Power interruption from cable movement

Do not allow a cable to twist or tug on the USB-C PD input during RA rotation, GoTo or a meridian flip. An intermittent input can reboot the mount and remove motor holding torque. Secure cable loops to a stationary support where appropriate, then manually verify slack through the complete intended travel while power is off and the telescope is supported.

Check both GEM pier-side paths and, if using AltAz mode, the whole planned azimuth travel. If a cable snags, stop movement before reaching into the setup. Recheck routing whenever a camera, guider or mini PC is added.