1.1 Safety information​

Read the safety messages before installing or operating the mount. This manual uses three signal words. The word and icon identify the message level; color is an additional cue.

NOTE

Operating requirements, compatibility information and helpful explanations.

CAUTION

Conditions that can damage the mount, telescope, power supply, accessories or cables. Follow the stated precaution before proceeding.

WARNING

Hazards that can cause injury, including falling equipment, moving parts and unsafe solar observation. Stop and resolve the hazard before proceeding.

General safety precautions​

WARNING · Adults only; keep clear of moving equipment

The WD-15E is not intended for children to use. Keep children and bystanders away from the telescope, counterweights and cables. Never put fingers, hands or any other part of the body in a gap that can narrow as the axes move. During GoTo or high-speed slewing, pinch points between the mount, telescope and support can close rapidly. Inspect the full travel, keep clear and use STOP for unexpected movement.

WARNING · Support the load before removing power

The WD-15E has no mechanical RA brake. Its motor provides holding torque only while appropriately powered. If input power is disconnected, interrupted or insufficient, an unbalanced optical load may move unexpectedly. Secure the telescope and any counterweights, balance the arrangement conservatively and support the load before unplugging the mount or loosening a clamp. Do not rely on USB-PD power alone to hold an unsafe load.

WARNING · Smoke, sparks or abnormal movement

If you notice sparks, smoke, a burning smell, excessive heat or unexpected movement, stop using the equipment. Press STOP if you can reach it safely. Isolate the USB-C input supply from a safe position; do not touch hot or damaged parts. Do not reconnect power to test whether the problem has cleared. Contact WarpAstron support before reuse.

WARNING · Solar observation

Never look at the Sun through a telescope or finder without suitable, correctly installed solar filters and a safe solar-observation procedure. Prevent an unfiltered instrument from pointing at the Sun.

CAUTION · Keep electrical connections dry

Use only a compatible, adequately rated USB-C PD source, cable and adapter. Keep the mount and all plugs dry. An AC mains adapter, its plug and extension connection must remain in a dry, protected location; do not use them outdoors where rain, spray, dew or condensation may reach them. Never connect a wet or damaged cable.

Secure the mount to a stable tripod or pier before attaching an optical load. A head resting on a table may seem stable yet tip when its latitude or axis position changes. Chapter 06 explains EC HA Limit, AEB and coordinate-based limits; none replaces physical clearance checks.

1.2 About this manual​

This English manual covers the WD-15E and the supplied 2026 Advanced Hand Controller (AHC). Begin with Chapter 02 for the first observing session. The AHC menu names refer to the AHC 1.1.0 interface; check the versions actually installed on your mount and controller before using a version-dependent feature.

WD-15E, WD-20E and WD-20EP are different products. Their firmware files, power inputs, saddle functions and load ratings are not interchangeable. Confirm the physical model label before connecting an accessory or updating firmware.

1.3 Product introduction​

The WARPDRIVE WD-15E is a compact servo direct-drive mount with an absolute encoder on the RA output axis. It supports German equatorial (GEM) and altazimuth operation. The optical payload rating is 8 kg without counterweights or 13 kg with counterweights, specified at a 20 cm RA lever arm. The head itself weighs 3.0 kg. These are separate configurations, not a promise that any 13 kg telescope or support arrangement is safe; see 3.5 Payload and counterweight setup.

WD-15E product view. The left saddle socket provides USB-PD accessory power; the right saddle socket is a mount-computer data connection. Read the markings on your own unit before connecting a cable.
WD-15E CAD rendering with model markings and distinct saddle sockets

The WD-15E uses USB-C PD input to run the mount. There is no power switch: connecting a live, negotiated power source starts the mount and can energize saddle Port A. Disconnecting that source removes motor holding torque. Plan the cable route and load support before connecting or removing power.

Its two saddle USB-C sockets have different functions: Port A (left) supplies USB-PD power to a compatible accessory, while Port B (right) provides a mount PC data connection only. Port B is neither a second PD output nor a general-purpose USB hub. See 4.9 Saddle power and data.

The operating functions include manual movement, GoTo, tracking, guiding, Home and Park. The AHC adds a touchscreen, joystick, GPS and supported Wi-Fi/BLE connectivity. The mount firmware uses OnStepX-compatible control interfaces; Chapter 04 covers connection and software setup.

The safety functions have distinct purposes: EC HA Limit monitors encoder-based RA travel even if sky coordinates are wrong; AEB reacts to abnormal motor loading after detection; meridian and altitude limits use the current pointing coordinate system. Chapter 06 explains their settings and limitations.

1.4 Getting to know the mount​

Identify the saddle, body, latitude support and panel on your own mount. The head is compact, but a loaded telescope can still create a large tipping moment.
WD-15E side view showing the saddle, body, latitude support and panel
Part or interfaceFunction
Dual-profile saddleClamps a compatible Vixen or Losmandy dovetail. Support the telescope while adjusting the clamps.
Saddle Port A, leftUSB-C PD power output for one compatible accessory; up to 5 A subject to negotiation, input power and cable rating.
Saddle Port B, rightUSB-C mount PC data connection. It does not provide the WD-20EP's second powered saddle channel.
Mount USB-C PD inputPowers the WD-15E. Connect a suitable 20 V / 5 A USB-C PD source, or an approved 12–24 V / 5 A DC-to-USB-C input cable. No power switch is provided.
PC and HC interfacesUse the labeled computer and Advanced Hand Controller connection routes; a matching USB-C shell does not make these ports interchangeable.
Home controlInitiates the mount's physical Home routine according to the installed firmware. Keep the path clear.
Latitude and azimuth adjustersSet the polar-axis direction for GEM operation.
M12 × 1.75 shaft socketAccepts a compatible counterweight shaft; the shaft and weights are not automatically included.

Front-panel controls and indicators​

Identify the labels on your own mount before connecting equipment. The WD-15E front panel has a USB-C PD POWER input, a HOME button, PC and HC connections, and three indicators. It has no power switch; connecting a live, compatible input supply powers the mount.

WD-15E front-panel connections and controls. POWER is the USB-C PD input, not a switch; PC and HC have different functions.
WD-15E front panel: PC, HC, USB-C POWER input and HOME button
Control / indicatorFunction and check
USB-C PD POWER inputConnect a compatible, adequately rated source to power the mount. There is no front-panel power switch; see 4.3 Wired connections.
HOME buttonHold for approximately 0.5 seconds, then release, to start a physical return to Home. The blue STAT light becomes continuously lit during the operation. Holding too long or pressing again cancels the return; see 5.4 Home.
PWR indicatorContinuously lit red: normal powered operation. This light alone does not confirm a controller connection, correct coordinates or safe movement.
Blue STAT indicatorFlashing blue: tracking. Continuously lit blue: GoTo or slewing, including the Home return. Confirm actual motion and completion in the AHC rather than relying only on the light.
EC encoder-status indicatorFlashing green: normal encoder status. Flashing red: encoder fault; stop movement and check the reported encoder/reference status before continuing. A green indication alone does not confirm that EC HA Limit is enabled or Home is valid.
PC and HC connectionsConnect only the device and cable specified for each labeled interface; see 4.3 Wired connections.
Indicator positions on the WD-15E panel: PWR, STAT and EC from left to right. The lenses are shown unlit; use the state guide below to interpret them.
PWR, STAT and EC light-pipe positions on the WD-15E panel
Same color and blink-pattern guide as WD-20E. The light labeled STATUS in this shared image is labeled STAT on the WD-15E panel. Each row describes one indicator independently; lit and unlit symbols show the two phases of a flashing light.
EC-series indicator-state guide: steady red PWR means powered operation; flashing blue STATUS, labeled STAT on WD-15E, means tracking; steady blue means GoTo, slewing or Home; flashing green EC means normal encoder status; flashing red EC means an encoder fault
View an animated indicator-state example
Same animation as WD-20E; STATUS in the image is STAT on WD-15E. The 700 ms on/off intervals are for explanation and are not the mount's specified firmware blink frequency.
Shared EC-series animation comparing continuously lit and flashing PWR, STATUS or STAT, and EC indications

The three lights serve different purposes. Neither PWR nor EC confirms that homing is complete or that movement is safe. If an indication is unexpected, stop and check the AHC and encoder status before continuing.

CAUTION · Similar USB-C sockets have different electrical roles

Identify input, output, data and HC by their labels, not by plug shape. Never attach an accessory power lead to a data-only or controller socket, or feed the mount through a saddle output. Disconnect input power before changing accessory power wiring, after making the unpowered load safe.

1.5 Package contents and optional accessories​

The official WD-15E product listing identifies these supplied items:

  • WD-15E mount head and 2026 Advanced Hand Controller.
  • USB-C-to-USB-A data cable for a computer connection.
  • 1 m USB-C-to-USB-C cable for the AHC connection or a suitable 100 W PD connection.
  • 2 m USB-C-to-USB-C cable for mount power.
  • 1 m USB-C PD-to-12 V DC, 5 A accessory-output cable with a 5.5 × 2.5 mm device plug.
  • Soft case and hex wrench.

The PD-to-DC cable is for powering a compatible 12 V accessory from saddle Port A. It is not the mount's input cable. The listing does not identify an AC adapter, tripod, counterweight shaft or counterweights as standard package items; check your order configuration and supplied hardware. Do not assume a WD-20EP adapter or cable is included or suitable.

1.6 Specifications​

ItemWD-15E
Operating modesEquatorial / altazimuth
RA and DEC reducersSize 14 strain-wave reducers on both axes
DriveBLDC servo direct drive; dual-encoder RA with output-axis absolute encoder
Mount head mass3.0 kg (6.6 lb)
Optical payload8 kg standard without counterweights; 13 kg with counterweights, at 20 cm RA lever arm
Mechanical brakeNone; motor holding torque is present only while appropriately powered
SaddleVixen and Losmandy profiles
Saddle Port A (left)USB-PD 3.1: 5/9/12/15/20 V profiles and PPS up to 20 V; 5 A maximum subject to negotiation and input/cable capacity
Saddle Port B (right)USB mount PC connection; data only
Counterweight-shaft threadM12 × 1.75
Slew rate5°/s standard; up to 10°/s maximum
Latitude adjustment0–90° using three coarse positions with a 30° fine range in each position
Azimuth adjustment±8°
Operating temperature−25 to +45°C
Home referenceRA absolute encoder; DEC optical homing sensor
Mount power inputUSB-C PD 3.0 20 V / 5 A, or approved 5.5 × 2.5 mm DC-to-USB-C input cable 12–24 V / 5 A
Control protocolsASCOM / INDI / LX200 / INDIGO through supported drivers
Time, GPS and wirelessGPS and Wi-Fi/BLE functions through the supplied AHC; confirm controller and firmware support

Specifications and included items follow the official WD-15E product page. For mount-to-adapter geometry, consult the official WD-15E dimensional drawing rather than the WD-20E/WD-20EP drawing. Confirm the actual hole pattern, screw engagement and accessory fit on your unit before mounting.

NOTE · Rated output depends on the power source

A USB-PD profile is available only when the source, cable and connected device negotiate it and sufficient input power remains for mount movement. A lower-voltage or current-limited input may prevent higher-voltage or high-power saddle profiles; confirm the actual negotiated output. The 20 V / 5 A profile is a 100 W theoretical USB-C output ceiling, not an additional 100 W supplied independently of the mount's input budget.

WarpAstron Optical Co., Ltd.